Overview

Application field of GDYS-601SB * * agent and its by-product detector: Suitable for rapid determination of chlorine dioxide, residual chlorine, total chlorine, chlorite, ozone and formaldehyde in drinking water and source water after * * treatment. The GDYS-601SB * * reagent and its byproduct detector consists of a host, sample pretreatment equipment, and reagent kit, and is suitable for field and laboratory use.

Product Details

GDYS-601SB**Agent and its byproduct detector

(1)GDYS-601SB**Application fields of agent and its byproduct detection instrument:

Suitable for rapid determination of chlorine dioxide, residual chlorine, total chlorine, chlorite, ozone, and formaldehyde in post treated drinking water and its source water.(II)GDYS-601SB**Instrument features for detecting agents and their by-products:

1. Detection method: The detection methods for residual chlorine, total chlorine, chlorine dioxide, and ozone comply withDPDThe law(GB/T 5750.11-2006)The formaldehyde detection method complies withAHMTThe law(GB/T 5750.10-2006).

2. Instrument composition: It consists of a host, sample pretreatment equipment, and reagent kit, and is suitable for field and laboratory use.

3. Optical path system: Solid state light-emitting devices are used as both light sources and monochromators/Monochromator, colorimetric tank, sensor integrated, no moving parts, pulse power supply method, light source service life up to10Compared with the conventional spectroscopic system, the optical system has a simpler structure, enhances the seismic and moisture resistance performance of the instrument, and greatly improves the accuracy, sensitivity, and reliability of the instrument.

4. Built in curve: The instrument has a built-in working curve, which does not require the configuration of standard solutions. After zero point calibration with matching reagents, rapid quantitative determination of samples can be achieved.

5. Measurement method: The sample color development and measurement are carried out in the same sealed container (cylindrical), without the need for transfer, which improves detection accuracy. A single channel can achieve multi parameter detection.

6. Specialized reagent kit: equipped with specialized pre made reagents, shortening the preparation time of reagents, easy to operate, and convenient to use.

7. Power supply method: Adopting9 VPowered by batteries, it meets the needs of laboratory testing and supports on-site testing. It also has self diagnosis of battery level and energy-saving function, automatically indicating insufficient battery level. When the instrument is not in use30Automatically shut down in minutes.

8. Consumables and accessories: Provide complete specialized pre-treatment equipment and consumables, one-stop service.

(3)GDYS-601SB**Technical specifications of the agent and its byproduct detector:

1. Light source: Ultra high brightness light-emitting diode

2. Wavelength:520nm,538nm

3. Determination of lower limit:

Residual chlorine:0.01 mg/L

Total chlorine:0.01 mg/L

Chlorine dioxide:0.02 mg/L

Chlorite:0.05 mg/L

Ozone:0.05 mg/L

Formaldehyde:0.05 mg/L

4. Measurement range:

Residual chlorine:0.00~2.50 mg/L

Total chlorine:0.00~2.50 mg/L

Chlorine dioxide:0.00~3.00 mg/L

Chlorite:0.00~2.00 mg/L

Ozone:0.00~2.50 mg/L

Formaldehyde:0.00~1.50 mg/L

5. Measurement accuracy: ±5%

6. Power requirements:DC,9 V

7. Size:190x110x95 mm

8. Weight:0.4 kg

(IV)GDYS-601SB**Configuration of reagent and its byproduct detector:

1. Colorimetric instruments1set

2. Reagents1Set up(50Next time)