Brief description: The GCTNS-6000 sulfur and nitrogen analyzer uses UV fluorescence method to determine the total sulfur content and chemiluminescence method to determine the nitrogen content, which improves the ability to resist impurity interference and avoids the complex operation of the titration cell by the electric method and the unstable factors caused by it, greatly improving the sensitivity of the instrument. The key components of the system are imported, ensuring reliable performance of the entire machine.
Product Details
brand
Self operated brand
Price range
discuss personally
Origin category
domestic
application area
Environmental protection, chemical industry, biotechnology, petroleum, energy
GCTNS-6000typeSulfur and nitrogen element analyzeruseDetermination of total sulfur content using ultraviolet fluorescence methodDetermination of nitrogen content by chemiluminescence methodThe ability to resist impurity interference has been improved, avoiding the cumbersome operation of the titration cell caused by the electric method and the resulting unstable factors, greatly enhancing the sensitivity of the instrument. The key components of the system are imported, ensuring reliable performance of the entire machine.
1. Characteristics: be based onWindowsChinese operation interface, direct human-machine dialogue. The collection, processing, storage, and printing of data are controlled by computers.The instrument automatically adjusts the gas flow rate without the need for manual adjustment; Control the sampler through computer; Added gas pressure abnormal alarm function.
2The standard for instrument execution is:
SH/T 0689-2000
Determination of total sulfur content in light hydrocarbons, engine fuels, and other oil products using ultraviolet fluorescence method
ASTM D 5453 -2006
UV fluorescenceDetermination of light hydrocarbons by optical measurement method,Spark ignition engine fuel,Standard Test Method for Total Sulfur Content in Diesel Engine Oil and Engine Oil
EN ISO 20846:2004
petroleum productsDetermination of sulfur content in motor vehicle fuelsUV fluorescence analysis method
GB 17930-2011
Motor Gasoline
GB 19147-2009
automobilefirewoodoil
ISO 20846-2011
petroleum productsDetermination of sulfur content in automotive fuels
BS EN 15486-2007
Ethanol is a mixed component of petroleum.Determination of sulfur content
SH/T 0657-1998
Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons by Oxidative Combustion and Chemiluminescence Method
ASTM D4629-2010
injection/Standard Test Method for Trace Organic Compound Nitrogen in Liquid Petroleum Hydrocarbons by Insertion of Oxidized Fuel and Chemiluminescence Method
SH/T 0704-2001
Method for determination of nitrogen content in petroleum and petroleum products(Boat injection chemiluminescence method)Petrochemical Industry Standards
ASTM D5762-2010
Test Method for Nitrogen in Petroleum and Petroleum Products by Ship Inlet Chemiluminescence Method
ASTM D6069-2001
Standard Test Method for Trace Nitrogen in Aviation Hydrocarbons by Oxidative Combustion and Reduction Pressure Chemiluminescence Detection
3System configuration:
Standard configuration: Computer+GCTNS-6000System+Liquid sampler
Other optional items: gas injectorsolid sampler、Mass flowmeter
GCTNS-6000Sulfur and nitrogen element analyzerTechnical parameters:
Technical Parameter Basic parameters: Sample types: liquid, solid, and gas Measurement methods: UV fluorescence method (S), chemiluminescence method (N) Sample injection volume: Solid sample: 1-90mg Liquid sample: 2-25 μ L Gas sample: 1-10mL Measurement range: 0.05-50000 ppm (mg/L) (high concentration can be diluted, low concentration gas samples can reach 0.1 ppm)
GCTNS-6000Sulfur and nitrogen element analyzeradvantage
1. The ozone disruptor adopts high-temperature decomposition method.
2. Built in electronicsMass flowmeter,Gas FlowThe quantity is automatically controlled by the operating software, the program tracks and monitors automatically, and the numbers are displayed at a glance.
3. The instrument is equipped with an automatic alarm function for abnormal gas pressure.
4. Digital tracking display of gas flow rate and pressure throughout the entire process.
5. Computer controlled sampler automatically injects samples without manual operation.
6Personalized operation interface and printing format can be designed according to user requirements.
7The computer controls the entire process of analysis, data processing, etc., and displays the working status of the entire process.
8The instrument has the function of recording operation steps and detection processes, which can query historical operation processes and data records, meeting audit needs.
9. The nitrogen reaction chamber enhances the reaction intensity between nitric oxide and ozone, as well as rapidly discharges exhaust gas and reduces tailing.
10The aromatic hydrocarbon barrier filtration system and detection system with selective permeable membrane are impossible to contaminate.
11Specially made quartz cracking tubeNo need to disassemble or replace, completely solving the problem of carbon buildup in combustion tubes.
12The instrument is equipped with a gas filtration and purification system.
13The key components are imported components,Reduced instrument noise and improved detection sensitivity..