Overview

The full spectrum water quality analyzer is a water quality analysis device developed by Shenbei Scientific Instruments based on a pulsed xenon lamp light source. The instrument has built-in measurement of all parameters (60 indicators), and its measurement principle conforms to the recognized methods of the environmental protection industry. It also supports two colorimetric methods: colorimetric tube and colorimetric dish. Its 8-inch IPS level high-definition touch screen is equipped with the Glos water quality detection system, which integrates water quality analysis, photometric measurement, construction curve, data batch printing, export, guided detection, batch detection and other applications.

Product Details

Full spectrum water quality analyzerIt is a water quality analysis equipment developed by Shenbei Scientific Instruments based on pulse xenon lamp light source. The instrument has built-in measurement of full parameters (60 indicators), and its measurement principle conforms to the recognized methods of the environmental protection industry. It also supports two colorimetric methods: colorimetric tube and colorimetric dish. Its 8-inch IPS level high-definition touch screen is equipped with Glos water quality detection system, which integrates water quality analysis, photometric measurement, construction curve, data batch printing, export, guided detection, batch detection and other applications.

全光谱水质分析仪

Application field
Widely used in scientific research, universities, sewage treatment plants, water environment testing, enterprise sewage self inspection and other fields.

全光谱水质分析仪

Features

01 Pulse xenon lamp light source, no preheating required, ready to use upon startup.
02 The determination of total nitrogen using the national standard ultraviolet method has stronger anti-interference ability and does not require the preparation of concentrated sulfuric acid, making it safer.
03 Equipped with Glos water quality intelligent detection system, making detection simpler and more intelligent.
04 Paired with a dual color system, it supports both tube color comparison and dish color comparison.
05 achievablesongLine, providing custom calibration of coefficient curves and sample curves.
06 Equipped with an 8-inch 1024 × 768 resolution IPS level high-definition capacitive touch screen.
07 Measurement data and program updates can be exported through the built-in USB interface.
08 Built in thermal printer, supports automatic printing and batch printing.
09 Touch to operate stereo sound feedback, providing a more comfortable operating experience with just a few clicks.
10 ABS material, high-strength, corrosion-resistant, and high-temperature resistant shell.
11 Equipped with a dual temperature zone digestion instrument and dual temperature dual control, the efficiency is doubled.
12 Equipped with a customized Greencaire pipette, it reduces errors in water sampling and is more stable.
13 More than 60 types of supporting reagents and consumables can be selected for direct use, which is simple and efficient.





technical indicators

Light source type Pulse xenon lamp light source
optical lifetime Blink 1 billion times, about 10 years
optical system Proportional dual beam optical system
wavelength range 190-1100nm
Wavelength accuracy ±0.8nm
wavelength resolution 0.5nm
indication error ≤±3%
repetitiveness ≤±1%
Optical stability ≤± 0.001Abs/20 minutes
Colorimetric method Tube dish dual colorimetric cell
Printing method 58mm miniature thermal printer
operating system Equipped with Glos water quality intelligent detection system
screen display 8-inch 1024 × 768 IPS high-definition capacitive touch screen
data storage 100000 pieces
Device Function Water quality analysis, photometric measurement, data management, self built coefficient curve, self built standard curve, USB data export, etc
Instrument power supply DC 12V,5A
Instrument size 430mm×363mm×165mm
Instrument weight About 7.7kg



horizontal comparison


Pulsed xenon lamp Tungsten lamp+deuterium lamp Monochrome LED solid-state cold light source
Spectral type Continuous spectrum Continuous spectrum LED monochrome spectrum
spectral range 190-1100nm 190-1100nm Composed of single or multiple monochromatic LEDs (does not support detection of wavelengths below 350nm, such as national standard total nitrogen detection)
optical path system Monochromator Monochromator Narrowband filter+monochrome LED solid-state cold light source
Power on preheating time No preheating required 20 minutes No preheating required
service life Blink 1 billion times, about 10 years 2000 hours, approximately 1 year 100000 hours

Pulsed xenon lamp Tungsten lamp+deuterium lamp Monochrome LED solid-state cold light source
Spectral type Continuous spectrum Continuous spectrum LED monochrome spectrum
spectral range 190-1100nm 190-1100nm Composed of single or multiple monochromatic LEDs (does not support detection of wavelengths below 350nm, such as national standard total nitrogen detection)
optical path system Monochromator Monochromator Narrowband filter+monochrome LED solid-state cold light source
Power on preheating time No preheating required 20 minutes No preheating required
service life Blink 1 billion times, about 10 years 2000 hours, approximately 1 year 100000 hours




Full parameter indicators

serial number Test Item Range (expandable) detection limit Testing Standard
01 COD 0-15000mg/L 5mg/L HJ/T 399-2007
02 Ammonia nitrogen - Nessler 0-50mg/L 0.05mg/L HJ535-2009
03 Ammonia nitrogen salicylic acid 0-10mg/L 0.01mg/L HJ536-2009
04 Total Phosphorus 0-16mg/L 0.02mg/L GB/T 11893-1989
05 Total phosphorus vanadium molybdenum yellow 0-30mg/L 0.2mg/L Vanadium molybdenum yellow spectrophotometric method
06 Total Nitrogen 0-250mg/L 0.05mg/L Alkaline persulfate digestion photometric method
07 *Total nitrogen 0-150mg/L 0.05mg/L (Applicable only to 820) HJ 636-2012
08 chroma 0-500PCU 5PCU GB/T 11903-1989
09 turbidity 0-100NTU 1NTU GB/T 13200-1991
10 suspended solids 0-500mg/L 1mg/L GB 11901-1989 Improvement
11 Copper BCO 0-1mg/L 0.04mg/L Dicyclohexanone Oxalidomide Dihydrazide spectrophotometric method
12 Copper bis quinoline 0-5mg/L 0.1mg/L GB/T 223.91-2021
13 *Copper 5-75ug/L 5pg/L (Boiler water microgram level)
14 Nickel - ultra-low 0-1mg/L 0.002mg/L PAN spectrophotometric method
15 Nickel - National Standard 0-4mg/L 0.1mg/L GB 11910-89
16 Iron PHEN 0-5mg/L 0.02mg/L HJ/T345-2007
17 *Iron 0-200ug/L 10ug/L (Boiler water microgram level)
18 Zinc Zinc Reagent 0-4mg/L 0.2mg/L GB/T 10656-2022
19 hexavalent chromium 0-1mg/L 0.01mg/L GB7467-87
20 total chromium 0-1mg/L 0.01mg/L GB7466-87
21 Cobalt PAN 0-2mg/L 0.02mg/L PAN spectrophotometric method
22 Cobalt - National Standard 0-0.5mg/L 0.01mg/L HJ 550-2015
23 Manganese potassium permanganate 0-16mg/L 0.02mg/L GB 11906-1989
24 Manganese formaldehyde oxime 0-6mg/L 0.025mg/L HJ/T 344-2007
25 COD Mn Direct Spectroscopy 0.5-5mg/L 0.25mg/L Direct spectrophotometry GB11892-89
26 COD Mn chlorine resistant spectrophotometry 0.1-4.5mg/L 0.25mg/L Chlorine resistant spectrophotometry GB11892-89
27 aniline 0-3mg/L 0.03mg/L GB11892-89
28 sulfide 0-1mg/L 0.01mg/L HJ 1226-2021
29 volatile phenol 0-2mg/L 0.01mg/L HJ503-2009
30 Qinghua substance 0-0.5mg/L 0.01mg/L HJ484-2009
31 fluoride 0-1.6mg/L 0.02mg/L HJ 488-2009
32 chloride 0-15mg/L 0.1mg/L Mercury thiocyanate spectrophotometric method
33 silicon dioxide 0-5mg/L 0.01mg/L GB/T 12149-2017
34 residual chlorine 0-3mg/L 0.02mg/L HJ 586-2010
35 Total residual chlorine 0-3mg/L 0.02mg/L HJ 586-2010
36 Chlorine dioxide 0-5mg/L 0.05mg/L GB/T 5750.11-2023 On site DPD method
37 nitrite 0-0.2mg/L 0.003mg/L GB7493-87
38 Thiocyanate salt 0-20mg/L 0.2mg/L HG/T 6072-2022
39 Nitrate nitrogen 0-20mg/L 0.1mg/L Color changing acid spectrophotometric method
40 phosphate 0-1.6mg/L 0.02mg/L GB 11893-89
41 Phosphate Vanadium Molybdenum Yellow 0-30mg/L 0.2mg/L Vanadium molybdenum yellow spectrophotometric method
42 sulfate 8-200mg/L 2mg/L HJ/T342-2007
43 Anionic surfactant 0-2mg/L 0.02mg/L GB/T7494-87
44 Formaldehyde in water 0-3mg/L 0.05mg/L Acetylacetone HJ 601-2011
45 ozone 0-1mg/L 0.01mg/L GB/T 5750.11-2023
46 hydrogen peroxide 0-50mg/L 0.5mg/L GB5009.226-2016
47 Total alkalinity 0-300mg/L 5.0mg/L Spectrophotometry
48 Total Hardness 0-100mg/L 5.0mg/L Spectrophotometry
49 urea 0-10mg/L 0.1mg/L GB/T18204.2-2014
50 Cyanuric acid 5-50mg/L 5.0mg/L CJ244-2007
51 Volatile fatty acids 0-60mmoL/L 0.5mmoL/L High-speed railway photometry
52 calcium 5-100mg/L 5mg/L Ortho methyl phthalein complex ketone photometric method
53 magnesium 5-100mg/L 5mg/L GB/T 6900-2006
54 silver 0-0.7mg/L 0.02mg/L HJ 489-2009
55 lead 0-6mg/L 0.1mg/L GB/T 223.29-2008
56 aluminium 0-0.25mg/L 0.005mg/L GB/T 5750-2023
serial number Gas series Range (expandable) detection limit Testing Standard
57 ammonia 0-25ug 0.4ug 《HJ533-2009》《GBZ/T 160.29-2004》
58 sulfur dioxide 0-12ug 0.12ug 《HJ482-2009 》《GBZ/T 160.33-2004》
59 Air formaldehyde 0-5ug 0.02ug 《GB/T 18204.2-2014 》
60 hydrogen sulfide 0-5ug 0.05ug Methylenediamine spectrophotometric method "GBZ/T 160.33-2004
61 hydrogen chloride 0-40ug 1.6ug 《HJ-T27-1999》《GBZ/T 160.37-2004 》
62 chlorine gas 0-8ug 0.08ug 《HJ533-2009》《GBZ/T 160.37-2004 》