Introduction to Oxygen Inhaler Calibration Device: Oxygen inhalers are mainly used in medical central oxygen supply systems as terminal equipment for medical oxygen output. They are used to regulate oxygen flow, humidify oxygen, and provide emergency oxygen supply and oxygen inhalation for hypoxic patients in medical units. The accuracy and reliability of their performance will directly affect the personal safety of patients

Product Details

Introduction to Oxygen Inhaler Calibration Device:
Oxygen inhaler is mainly used in medical center oxygen supply systems, and is the terminal equipment for medical oxygen output. It is used to regulate oxygen flow, humidify oxygen, and provide oxygen inhalation for emergency oxygen supply and hypoxic patients in medical units. Its accurate and reliable performance will directly affect the personal safety of patients. It can not only accurately measure the instantaneous flow rate of oxygen, but also enable medical staff to understand the patient's oxygen inhalation status at the nurse station at any time. Scientific oxygen management has played a great role in ensuring the accuracy and reliability of medical measuring instruments, improving medical quality, and safeguarding the physical health of the people.
In the monitoring of adverse events in medical devices, it has been found that some medical institutions have experienced serious injuries to the eyes of accompanying personnel due to the bursting of "humidification bottles" and the damage of bursting fragments when using float type oxygen inhalers. In order to ensure the safety and reliability of oxygen inhalers, they must be regularly calibrated.
Our oxygen inhaler calibration device is designed to solve the above-mentioned problems.
Principle of Oxygen Inhaler Calibration Device:
Install the float type oxygen inhaler to be tested on the oxygen inhaler calibrator, connect the oxygen source with a connecting tube, and check if the pressure reducer leaks. Using the comparative method, read the oxygen indication value of the tested oxygen inhaler and the indication value of the flow bottle meter, and compare them with the indication values of the standard pressure gauge and standard flow meter to determine whether the oxygen inhaler is qualified. The moisture bottle should not rupture under a pressure of (0.35 ± 0.05) MPa.
This standard mainly consists of a float type oxygen inhaler calibrator, a medical oxygen cylinder, and a dedicated connecting tube.
Technical characteristics of oxygen inhaler calibration device:
Measurement range:
High pressure: (0-25) MPa (different ranges can be customized according to customer requirements)
Low pressure: (0-0.6) MPa (different ranges can be customized according to customer requirements)
Flow rate: (1~10) L/min (different ranges can be customized according to customer requirements)

Accuracy level:
Pressure: 0.1 level, 0.05 level, 0.02 level (optional)
Traffic: Level 1
Intuitive display: 7-inch true color touch screen, real-time display, oxygen pressure, output pressure, current flow rate
Convenience of operation: The calibration table is equipped with an oxygen flow switching valve, which can quickly switch between flow and pressure calibration ports to achieve the calibration of inhaler flow and pressure. The pressure regulator can adjust the pressure and is used to calibrate oxygen pressure gauges.