FDEF-40-1.8/3KV-4 * 6 Twist resistant Flexible CableUsage characteristics:
FDEF-40-1.8/3KV-4 * 6 Twist resistant Flexible Cablepurpose
FDEF-40-1.8/3KV-4 * 6 Twist resistant Flexible CableThe model and name
| model | rated voltage | name |
| FDEF-25(-40) | 450/750V 0.6/1kV 1.8/3kV | Copper core ethylene propylene rubber insulated chloroprene rubber sheathed wind power generation (cold resistant) torsion resistant flexible cable |
| FDES-25(-40) | Copper core ethylene propylene rubber insulated thermoplastic elastomer sheathed wind power generation (cold resistant) torsion resistant flexible cable | |
| FDGG-40(-55) | Copper core silicone rubber rubber insulation silicone rubber sheath wind power generation electricity cold resistant (cold resistant) torsion resistant flexible cable | |
| FDGU-40(-55) | Copper core silicone rubber rubber insulated polyurethane elastomer sheathed cold resistant (cold resistant) and torsion resistant flexible cable for wind power generation | |
| FDEU-40(-55) | Copper core, ethylene propylene rubber insulation, polyurethane elastomer sheath, cold resistant (cold resistant) and torsion resistant flexible cable for wind power generation | |
| FDEG-40(-55) | Copper core, ethylene propylene rubber insulation, silicone rubber sheath, cold resistant (cold resistant) and torsion resistant flexible cable for wind power generation | |
| FDEH-25(-40) | Copper core ethylene propylene rubber insulated chlorosulfonated polyethylene rubber sheathed wind power generation (cold resistant) torsion resistant flexible cable |
FDEF-40-1.8/3KV-4 * 6 Twist resistant Flexible CableProduct performance characteristics
(1) Physical and mechanical properties: The tensile strength of insulation shall not be less than 10.0MPa, and the elongation at break shall not be less than 300%; The tensile strength of the sheath shall not be less than 15.0MPa, and the elongation at break shall not be less than 400%;
(2) High flexibility: The finished cable should pass current load and voltage load bending tests, and should withstand 60000 bidirectional bends, that is, 120000 unidirectional bends, without any current break or short circuit between conductors.
(3) Twist resistance: The finished cable should be twisted at a speed of 360 °/S (alternating counterclockwise and clockwise twists of 360 ° once) and withstand 5 million times of bidirectional twisting, that is, 10 million times of unidirectional twisting. There should be no current interruption or short circuit between conductors