ET-04Composite gas detector
ET-04Type composite gas detector is a single type that can be configured in multiple ways(Infrared sensors and electrochemical sensors, such as:ozone,Ammonia, carbon monoxide,sulfur dioxide,Hydrogen sulfide, etc,See the list,Optional selection)The gas detection alarm device has a very clear large LCD display screen, sound and light alarm prompts, and a built-in pump. It can also detect dangerous gases in very unfavorable working environments and promptly remind operators to take precautions. Simultaneously transmit data remotely
Composite gas detectorfeature:
-Sound and light alarms, with color and blue screens displaying gas concentration.
-Large screen display of numbers, characters, instantaneous values, and peak values
-Equipped with a built-in suction pump, it can suck gas from tens of meters away into the instrument for measurement
-Outstanding audio sound alarm
-Equipped with a charger, easy to carry, and flexible to use
-Self check the display, battery, sensor, and sound and light alarm functions when turned on or needed
-Safety reminder: Regular flashing lights and sound prompts
-ET-04 Composite Gas DetectorCan simultaneously support infrared sensors, electrochemical sensors, and multiple configurations6Seed, the instrument comes with the factory4Gas detection is a type of sensor that users can choose according to their requirements, and the sensor can be replaced by the user.
Built in instrument: system self-test and measurement software
Composite gas detectorMain sensor technical indicators
|
Technical Specifications: l You can freely choose between infrared sensors and electrochemical sensors,Assemble a composite gas analyzer, l Multi parameter gas detector, composite gas detector, multi parameter gas analyzer, gas detector, gas analyzer,ET-04Composite gas detector |
range |
essence degree |
Small reading |
response time |
|
|
Formaldehyde detector |
0-10.00ppm |
<±5%(F.S) |
0.01ppm |
≤25second |
|
|
oxygen(O2) |
0-30%Vol |
<±5%(F.S) |
0.1%Vol |
≤15second |
|
|
Ozone detector |
0-20ppm |
<±5%(F.S) |
0.01 ppm |
≤30second |
|
|
flammable gas(EX) |
0-100%LEL |
<±5%(F.S) |
1%LEL |
≤5second |
|
|
carbon monoxide(CO) |
0-100ppm |
<±5%(F.S) |
0.1ppm |
≤25second |
|
|
hydrogen sulfide(H2S) |
0-100.0ppm |
<±5%(F.S) |
0.1ppm |
≤30second |
|
|
sulfur dioxide(SO2) |
0-100ppm |
<±5%(F.S) |
0.1ppm |
≤30second |
|
|
nitric oxide(NO) |
0-250ppm |
<±5%(F.S) |
1ppm |
≤60second |
|
|
nitrogen dioxide(NO2) |
0-20ppm |
<±5%(F.S) |
0.1ppm |
≤25second |
|
|
chlorine gas(CL2) |
0-20ppm |
<±5%(F.S) |
0.1ppm |
≤30second |
|
|
ammonia(NH3) |
0-100ppm |
<±5%(F.S) |
1ppm |
≤50second |
|
|
hydrogen(H2) |
0-1000ppm |
<±5%(F.S) |
1ppm |
≤60second |
|
|
hydrogen cyanide(HCN) |
0-50ppm |
<±5%(F.S) |
0.1ppm |
≤200second |
|
|
hydrogen chloride(HCL) |
0-20ppm |
<±5%(F.S) |
0.1ppm |
≤60second |
|
|
phosphine(PH3) |
0-5-1000 ppm |
<±5%(F.S) |
0.01/1ppm |
≤25second |