Detailed description of constant temperature air bath oscillator
Function and use of constant temperature air bath oscillator:
The constant temperature air bath oscillator is a biochemical instrument that combines a temperature controlled constant temperature incubator and oscillator. It is mainly suitable for the oscillation cultivation of various liquid and solid compounds such as biology, biochemistry, cells, and bacterial strains in various universities, medical, petrochemical, health and epidemic prevention, environmental monitoring and other scientific research departments.
The main features of the constant temperature air bath oscillator are:
A: Accurate numerical display of temperature control.
B: Provide oxygen replenishment holes and a constant temperature working chamber with sufficient oxygen replenishment.
C: Equipped with mechanical timing.
D: The universal spring bottle rack is particularly suitable for the cultivation and preparation of biological samples for various comparative experiments.
E: Stepless speed regulation, smooth operation, easy and safe operation.
F: The inner cavity is made of stainless steel, which has good corrosion resistance.
Function and use of constant temperature air bath oscillator:
Air bath shaker (also known as air constant temperature shaker) is a biochemical instrument that combines a temperature controlled constant temperature incubator and shaker. It is mainly suitable for the oscillation cultivation of various liquid and solid compounds such as biology, biochemistry, cells, and bacterial strains in various research departments such as universities, medical institutions, petrochemicals, health and epidemic prevention, and environmental monitoring.
Main features of air bath oscillator:
A: Accurate numerical display of temperature control. B: Provide oxygen replenishment holes and a constant temperature working chamber with sufficient oxygen replenishment. C: Equipped with mechanical timing. D: The universal spring bottle rack is particularly suitable for the cultivation and preparation of biological samples for various comparative experiments. E: Stepless speed regulation, smooth operation, easy and safe operation. F: The inner cavity is made of stainless steel, which has good corrosion resistance. Air bath oscillator product model:
(1) CHA-SA type, air bath oscillator: belongs to the reciprocating type
(2) SHZ-82 type, air bath oscillator: belongs to the rotary type
(3) ZD-85 type, air bath oscillator: belongs to dual function.
Main technical performance of air bath oscillator:
| Indicator model | CHA-SA/THZ-82 reciprocating | THZ-82A/B Cyclotron | ZD-85 dual function |
| speed range | Start at -300r/min | Start at -300r/min | Start at -300r/min |
| Temperature control range | Room temperature -50 ℃ | Room temperature -50 ℃ | Room temperature -50 ℃ |
| Temperature control accuracy | ±1℃ | ±1℃ | ±1℃ |
| Vibration CC amplitude | 25mm | 20mm | 25,20mm |
| heating power | 300W | 300W | 300W |
| Bottled quantity | Test tube: ¢ 16 × 300 | Test tube: ¢ 16 × 300 | Test tube: ¢ 16 × 300 |
| timing range | 0-120min (or normally open) | 0-120min (or normally open) | 0-120min (or normally open) |
| power supply | Communication 220V 50Hz | Communication 220V 50Hz | Communication 220V 50Hz |
| Overall dimensions | 700×500×470 | 700×500×470 | 700×500×470 |
Notice before using the constant temperature air bath oscillator
1. Please read this manual carefully before use.
2. The working surface of the machine should not be excessively smooth (such as tiles, etc.).
3. The electrical rated parameters of the socket provided by the user should not be less than the electrical rated parameters of the machine, and there should be good grounding measures.
4. The whole machine is strictly prohibited from being used in an environment with direct sunlight.
5. The speed control should start slowly from low speed to high speed.
6. The machine may experience some displacement during high-speed oscillation, so it should be monitored by someone during use.
Instructions for using a constant temperature air bath oscillator:
1. Load the test bottle and maintain balance. If it is a dual function model, set the oscillation mode. (For detailed settings, please refer to the following diagram)
2. Connect the power and set the timer according to the surface scale of the machine. If you need to work for a long time, adjust the timer to the "normally open" position.
3. Turn on the power switch and set the constant temperature: (1) Place the control switch in the "Setting" section, and the temperature displayed on the screen will be the set temperature. Adjust the knob to set it to the desired temperature for your work. (The working temperature you set should be higher than the ambient temperature. At this time, the machine starts heating and the yellow indicator light is on. Otherwise, the machine will not work.) (2) Place the small switch of the control part on the "measurement" end. At this time, the temperature displayed on the screen is the actual temperature of the air inside the test box. As the temperature inside the box changes, the displayed number will also change accordingly. (3) When heated to the desired temperature, the heating will automatically stop and the green indicator light will turn on; When the heat inside the test chamber dissipates below the temperature you set, a new round of heating will begin.
4. Turn on the oscillation device: (1) Turn on the oscillation switch on the control panel, and the indicator light will turn on. (2) Adjust the oscillation speed knob to the desired oscillation frequency.
5. Cut off the power after work, and set the speed control knob and temperature control knob to the lowest point.
6. Clean the machine and keep it clean.
Precautions for constant temperature air bath oscillator:
1. Instruments should be placed on a sturdy workbench, with a clean and tidy environment and good ventilation.
2. The power socket provided by the user should have good grounding measures.
3. It is strictly prohibited to move the machine during normal operation.
4. It is strictly prohibited for objects to collide with the machine.
5. Children are strictly prohibited from approaching the machine to prevent accidents.
6. Before replacing the fuse, ensure that the power supply has been cut off.
7. After use, please clean the machine without leaving any water droplets or dirt residue.
Thermostatic air bath oscillator can be customized according to customer requirements
After sales service for constant temperature air bath oscillator: three guarantees and one year, lifetime maintenance!