E-mail
2909229930@qq.com
-
Phone
13306141112
-
Address
No. 180 Huaxing Road, Jintan Economic Development Zone, Jiangsu Province
Changzhou Yitong Analytical Instrument Manufacturing Co., Ltd
2909229930@qq.com
13306141112
No. 180 Huaxing Road, Jintan Economic Development Zone, Jiangsu Province
Changzhou Yitong Analytical Instrument Manufacturing Co., Ltd
2018Annual quotation(Analysis Instrument Section)
|
AIndoor environment detector |
||||||||||||||||||
|
Preface |
Instrument name |
type |
Technical Parameters |
price |
|
|||||||||||||
|
1 |
Formaldehyde analyzer |
ET-102 |
0.01~10ppmResolution:0.01 ppmDirect readingmg/m3 |
9800 |
|
|||||||||||||
|
2 |
Continuous radon detector |
1027 |
Range:0.1~999pCi/L,(AC/DCtransformer/Software), |
12000 |
|
|||||||||||||
|
3 |
Ammonia gas detector |
ET-NH3 |
Measurement range:0.1~50 ppm, accuracy:0.1 ppmPump suction |
9800 |
|
|||||||||||||
|
4 |
Ozone analyzer |
ET-O3 |
Measurement range:0.01~20 ppm, accuracy:0.1 ppmPump suction |
9800 |
|
|||||||||||||
|
5 |
UV ozone detector |
EUV-O3 |
Accuracy up to ±0.01ppm,The measurement range is determined by0~20ppm |
16000 |
|
|||||||||||||
|
|
Low concentration ultraviolet ozone detector |
EUV-O3 |
measurement range:0.001(1ppb)-1ppm |
19000 |
|
|||||||||||||
|
6 |
Dual path UV ozone detector |
EUV-O3A |
Dual light path,Accuracy up to ±0.01ppm,The measurement range is determined by0~20ppm |
20000 |
|
|||||||||||||
|
|
Dual path UV ozone detector |
EUV-O3A |
Dual light path,measurement range:0.001(1ppb)-1ppm |
23000 |
|
|||||||||||||
|
|
Portable Odor Gas Analyzer |
EUV-05 |
Detection of indoor organic toxic gases such as benzene, toluene, xylene, formaldehyde, etc |
29800 |
|
|||||||||||||
|
|
UV Odor Gas Detector |
EUV-06 |
Odorous gases are present185~360nmStrong absorption characteristic spectrum in the ultraviolet region |
79000 |
|
|||||||||||||
|
7 |
Palm style carbon dioxide analyzerImport |
CEA-700 |
Scope:0~10000 ppmAccuracy:1ppmInfrared method |
9800 |
|
|||||||||||||
|
8 |
Infrared carbon dioxide analyzer |
CEA-800 |
Scope:0~5000 ppmAccuracy:10ppmInfrared method,portable |
9800 |
|
|||||||||||||
|
7 |
Fresh air volume carbon dioxide detectorImport |
TELAIRE 7001P |
Fresh air volume:0~45m3/Person hour carbon dioxide:0~10000 ppm Wen Degree:0~50℃ Equipped with a built-in pump, the sampling speed is fast |
10 |
|
|||||||||||||
|
8 |
Carbon monoxide analyzer |
ET-CO |
0.0~100.0ppmPump suction,electrochemistry |
9800 |
|
|||||||||||||
|
9 |
Carbon monoxide detector (imported) |
T40 |
0~1000ppmAccuracy:1 ppm、electrochemistry |
4400 |
|
|||||||||||||
|
|
Infrared carbon monoxide analyzer |
ET-3015A |
0.0~50/100.0ppmPump suction, infrared method,National Standard Law |
24800 |
|
|||||||||||||
|
|
Infrared carbon monoxide analyzer |
ET-3015E |
0.0~50/100.0ppmPump suction, infrared method,National standard law upper computer software |
32000 |
|
|||||||||||||
|
|
Infrared oxygen/Two oxygen two in one |
ET-3015F |
Sampling method: built-in pump suction Measurement range:CO:0~50/100 CO2:0~5000 divide distinguish Rate:0.1×10-6CO;0.001% CO |
48000 |
|
|||||||||||||
|
11 |
epoxyEthane detector |
ET-C2H40 |
0~100.0ppmPump suction,electrochemistry |
9800 |
|
|||||||||||||
|
12 |
Hydrogen fluoride detector |
ET-HF |
0.0~100.0ppmPump suction,electrochemistry |
11000 |
|
|||||||||||||
|
13 |
Fluorine gas detector |
ET-F2 |
0.0~100.0ppmPump suction,electrochemistry |
11000 |
|
|||||||||||||
|
14 |
Chlorine gas detector |
ET-CL2 |
0.0~20.0ppmPump suction,electrochemistry |
9800 |
|
|||||||||||||
|
15 |
Hydrogen chloride detector |
ET-HCL |
0.0~20.0ppmPump suction,electrochemistry |
11000 |
|
|||||||||||||
|
16 |
Hydrogen cyanide detector |
ET-HCN |
0.0~50.0ppmPump suction,electrochemistry |
11000 |
|
|||||||||||||
|
17 |
Chlorine dioxide detector |
ET-CLO2 |
0.0~20.0ppmPump suction,electrochemistry |
9800 |
|
|||||||||||||
|
18 |
Nitrogen dioxide detector |
ET-NO2 |
0.0~20.0ppmPump suction,electrochemistry |
9800 |
|
|||||||||||||
|
19 |
Methane gas analyzer |
M40 |
Measurement range: 0~100% CH4Electrochemical method, with coal safety certification |
4400 |
|
|||||||||||||
|
20 |
Hydrogen sulfide analyzerImport |
T40 |
0~500ppmAccuracy:1 ppm、Electrochemical, pump suction |
4500 |
|
|||||||||||||
|
21 |
Hydrogen sulfide analyzer |
ET-H2S |
0.1~100ppmResponse time: ≤30Second, pump suction |
9800 |
|
|||||||||||||
|
22 |
Oxygen detector |
ET-O2 |
0.1~30%Response time: ≤15Second, pump suction |
9800 |
|
|||||||||||||
|
23 |
Hydrogen gas detector |
ET-H2 |
0-1000ppmResponse time: ≤15Second, pump suction |
9800 |
|
|||||||||||||
|
24 |
Combustible gas detector |
ET-EX |
0-100%LELResponse time: ≤15Second, pump suction |
9800 |
|
|||||||||||||
|
25 |
Sulfur dioxide analyzer |
ET-SO2 |
0.1~20ppmResponse time: ≤15Second, pump suction |
9800 |
|
|||||||||||||
|
|
Palm styleCOdetector |
ET-CO |
0-1000PPm,Response time: ≤15second,resolution1PPm |
1600 |
|
|||||||||||||
|
|
Palm styleCO2detector |
ET-CO2 |
0-5000PPm,Response time: ≤15second,resolution1PPm |
6000 |
|
|||||||||||||
|
|
Palm styleCH2Odetector |
ET-CH2O |
0-20PPm,Response time: ≤15second,resolution0.1PPm |
6000 |
|
|||||||||||||
|
|
Palm styleO3detector |
ET-O3 |
0-10PPm,Response time: ≤15second,resolution0.1PPm |
6000 |
|
|||||||||||||
|
|
Palm styleO2detector |
ET-O2 |
0-30%VOL,Response time: ≤15second,resolution0.1%vol |
2000 |
|
|||||||||||||
|
|
Palm styleNH3detector |
ET-NH3 |
0-100PPm,Response time: ≤15second,resolution1PPm |
4000 |
|
|||||||||||||
|
|
Palm styleH2Sdetector |
ET-H2S |
0-100PPm,Response time: ≤15second,resolution1PPm |
1600 |
|
|||||||||||||
|
|
Palm styleNO2detector |
ET-NO2 |
0-20PPm,Response time: ≤15second,resolution1PPm |
4000 |
|
|||||||||||||
|
|
Palm styleNOdetector |
ET-NO |
0-250PPm,Response time: ≤15second,resolution1PPm |
4000 |
|
|||||||||||||
|
|
Palm styleCL2detector |
ET-CL2 |
0-20PPm,Response time: ≤15second,resolution1PPm |
4000 |
|
|||||||||||||
|
|
Palm styleCLO2detector |
ET-CLO2 |
0-20PPm,Response time: ≤15second,resolution1PPm |
6000 |
|
|||||||||||||
|
|
Palm styleHCNdetector |
ET-HCN |
0-50PPm,Response time: ≤15second,resolution1PPm |
6000 |
|
|||||||||||||
|
|
Palm styleVOCdetector |
ET-VOC |
0-100PPm,Response time: ≤15second,resolution1PPm |
6000 |
|
|||||||||||||
|
|
Palm styleEXdetector |
ET-EX |
0-100%LE,Response time: ≤15second,resolution1%LEL |
1200 |
|
|||||||||||||
|
|
Palm styleC2H4Odetector |
ET-C2H4O |
0-100PPm,Response time: ≤15second,resolution1PPm |
4000 |
|
|||||||||||||
|
|
Palm styleSO2detector |
ET-SO2 |
0-20PPm,Response time: ≤15second,resolution1PPm |
4000 |
|
|||||||||||||
|
|
Palm style toluene/Xylene detector |
ET-DU |
0-20PPm,Response time: ≤15second,resolution1PPm |
6000 |
|
|||||||||||||
|
|
Palm styleCH4detector |
ET-CH4 |
0-100%LEL,Response time: ≤15second,resolution1%LEL |
1200 |
|
|||||||||||||
|
|
Palm styleCH4Infrared detector |
ET-CH4 |
0-100%VOL,Response time: ≤15second,resolution0.1%VOL |
6000 |
|
|||||||||||||
|
26 |
Four in one gas detector |
ET-04 |
You can choose any of the four sensors,as(CO,CO2,H2S,O3)Form a four in one gas analyzer. |
19800 |
|
|||||||||||||
|
27 |
Intelligent composite gas detector |
ET-04 |
You can choose any of the four sensors,Like(C2H40,OL,NH3,SO2)Form a four in one gas analyzer. |
19800 |
|
|||||||||||||
|
|
Palm style four in one detector |
ET-04 |
You can choose any of the four sensors,Conventional(LEL,O2,CO,H2S)Form a four in one gas analyzer. |
6000 |
|
|||||||||||||
|
28 |
Online four in one gas detector |
ET-08 |
The remote detection system is input by a mobile card, and at the same time, a computer operation host is connected to the computer, which can print and store data online. As long as one person operates, they can simultaneously monitor the online gas of hundreds of units |
200000 |
|
|||||||||||||
|
29 |
Four in one water quality detector |
ET-05 |
You can freely choose the water quality category,Form a four in one water quality analyzer. |
20000 |
|
|||||||||||||
|
30 |
Online water quality monitoring instrument |
ET-09 |
The implementation of unmanned operation in a positive sense has solved the problem that current instruments can only detect and cannot transmit data remotely in real-time. This instrument can utilize the current communication network to achieve remote detection data transmission within the coverage area of China Mobile. |
200000 |
|
|||||||||||||
|
33 |
Atmospheric dust detector |
PM10/2.5 |
Using the principle of laser.2Produce a test result every minute and measure:PM10ThePM2.5Instruments for particle number and mass concentration |
20000 |
|
|||||||||||||
|
|
Laser dust detector |
LD-5C |
Using the principle of laser.2Produce a test result every minute and measure:PM10ThePM2.5Instruments for particle number and mass concentration |
25000 |
|
|||||||||||||
|
34 |
Online air dust detector |
ET-08A |
andPCThe machine is connected to the data acquisition device and can remotely input the detection data to the control center or read the measurement values through a remote mobile phone |
38000 |
|
|||||||||||||
|
35 |
Online atmospheric dust detector |
ET-08B |
andPCThe machine is connected to the data acquisition device, which can remotely input the detection data to the control center or read the measurement values through a remote mobile phone, and add functions such as filtering and drying |
58000 |
|
|||||||||||||
|
36 |
Indoor Air Quality Testing System |
ET-10A |
Optional four types of sensors, andPM10andPM2.5Detector module |
50000 |
|
|||||||||||||
|
37 |
Environmental data acquisition device |
ET-100 |
Backend user management software that allows for easy management of a host system500A data acquisition device |
00 |
|
|||||||||||||
|
38 |
Personal measurement alarm device |
ET-900 |
Can detect four types of radiation, including X-rays, gamma rays, alpha rays, and beta rays
Dose rate:mR/hr:01 (1 µR)~100 mR/hr |
9800 |
|
|||||||||||||
|
39 |
Multi functional X-ray instrument |
ET-900+ |
Can detect four types of radiation, including X-rays, gamma rays, alpha rays, and beta rays
Dose rate:mR/hr:01 (1 µR)~100 mR/hr Can be connected to a printer |
19800 |
|
|||||||||||||
|
40 |
Handheld laser particle counter |
DT9880 |
6Channel error:5%, 2000000grain/ft3 |
13000 |
|
|||||||||||||
|
41 |
Landfill gas detector |
ET900 |
CH4:0-100%, O2:0-30%The CO2:0-20000ppmThe(H2S):0-500ppm、 |
20000 |
|
|||||||||||||
|
Public testing system box |
Instrument selection for detection system box |
|
||||||||||||||||
|
carbon dioxide |
carbon monoxide |
thermo-hygrometer |
noise meter |
illuminance meter |
anemometer |
|
||||||||||||
|
42 |
ET-1 |
CEA-800 |
T40 |
TES-1360 |
TES-1350A |
TES-1330 |
T405 |
29800 |
||||||||||
|
43 |
ET-2 |
CEA-800 |
ET-CO |
TES-1360 |
TES-1350A |
TES-1332 |
T405 |
32900 |
||||||||||
|
44 |
ET-3 |
Same as above, with additional radiation meter |
42900 |
|||||||||||||||
|
45 |
ET-4 |
Indoor pollution detection system box Can measure simultaneously (formaldehyde analyzer, ammonia analyzer, radon analyzer, carbon dioxide) |
58000 |
|||||||||||||||
|
Intelligent gas detection, mercury analyzer, fresh air volume |
||||||||||||||||||
|
Preface |
Instrument name |
Type |
Technical Parameters |
price |
||||||||||||||
|
1 |
Intelligent formaldehyde detector |
ETA-102 |
Measurement range (simultaneously displayed)ppmThemg/m3):0-9.99ppmor0-19.99ppmtemperature-20∽60℃ humidity:10-95%RHLarge color touch screen with256Group data storageUSBinterfaceSmall Reading0.01ppm |
13500 |
||||||||||||||
|
2 |
Intelligent carbon dioxide detector |
CEA-800A |
Measurement range:0-5000ppmOr (extended to)0~100%Instrument display:ppmThemg/m3Temperature and humidity measurement accuracy:1ppm.Large color touch screen with256Group data storageUSBinterface |
11500 |
||||||||||||||
|
3 |
Intelligent carbon monoxide detector |
ETA-CO |
Measurement range: (simultaneously displayed)ppmThemg/m3)Carbon monoxide:0-100ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.1ppm、 Large color touch screen with256Group data storageUSBinterface |
11500 |
||||||||||||||
|
4 |
Intelligent ammonia gas detector |
ETA-NH3 |
Measurement range: (simultaneously displayed)ppmThemg/m3)Ammonia gas:0.1-100ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:1ppm Large color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
5 |
Intelligent hydrogen sulfide detector |
ETA-H2S |
measurement range:(Simultaneously display)ppmThemg/m3)Hydrogen sulfide:0-100ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.01ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
6 |
Intelligent ozone detector |
ETA-O3 |
measurement range:(Simultaneously display)ppmThemg/m3)Ozone:0-20ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.01ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
|
Intelligent ozone detector |
ETA-O3 |
measurement range:(Simultaneously display)ppmThemg/m3)Ozone:0-2ppm temperature-20∽60℃. Humidity:10-95%RHSmall reading:0.001ppmLarge color touch screen with256Group data storageUSBinterface |
16000 |
||||||||||||||
|
|
Intelligent ozone detector |
ETA-O3 |
measurement range:(Simultaneously display)ppmThemg/m3)Ozone:0-5ppm temperature-20∽60℃. Humidity:10-95%RHSmall reading:0.01ppmLarge color touch screen with256Group data storageUSBinterface |
14500 |
||||||||||||||
|
7 |
Intelligent sulfur dioxide detector |
ETA-SO2 |
measurement range:(Simultaneously display)ppmThemg/m3)Sulfur dioxide:0-100ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.1ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
8 |
Intelligent ethylene oxide detector |
ETA-C2H40 |
measurement range:(Simultaneously display)ppmThemg/m3)0-19.99ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.01ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
9 |
Intelligent nitrogen dioxide detector |
ETA-NO2 |
measurement range:(Simultaneously display)ppmThemg/m3)Nitrogen dioxide:0-20ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.1ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
10 |
Intelligent nitric oxide detector |
ETA-NO |
measurement range:(Simultaneously display)ppmThemg/m3)Nitric oxide:0-250ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:1ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
11 |
Intelligent oxygen detector |
ETA-O2 |
measurement range:Oxygen:0-30%temperature-20∽60℃. Humidity:10-95%RHSmall reading:0.1%Large color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
12 |
Intelligent hydrogen cyanide detector |
ETA-HCN |
measurement range:(Simultaneously display)ppmThemg/m3)Hydrogen cyanide:0-50ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.1ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
13 |
Intelligent chlorine gas detector |
ETA-CL2 |
measurement range:(Simultaneously display)ppmThemg/m3)Chlorine gas:0-20ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.1ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
14 |
Intelligent chlorine dioxide detector |
ETA-CLO2 |
measurement range:(Simultaneously display)ppmThemg/m3)Chlorine dioxide:0-20ppmtemperature-20∽60℃. Humidity:10-95%RHSmall reading:0.01ppmLarge color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
15 |
Intelligent six in one gas detector |
ET-06A |
Detecting gases: any substance in the air4Toxic gases, temperature, humidity, etc6Parameters. Simultaneously display the concentration of gas:ppmThemg/m3,temperature, humidity*Color touch screen display with time and date memory function*It has data query function and data storage256Group, there isUSBinterface*. |
25000 |
||||||||||||||
|
16 |
Intelligent combustible gas detector |
ETA-EX |
measurement range:Gaseous gas:0-100%temperature-20∽60℃. Humidity:10-95%RHSmall reading:0.1%Large color touch screen with256Group data storageUSBinterface |
13500 |
||||||||||||||
|
17 |
Intelligent mercury analyzer |
ETCG-1 |
Using microcontroller control and calculation technology, directly display the concentration of mercuryng/lTemperature and humidity. No manual calculation is required. There is a data query function that can directly query the date, time, and measurement value of the measurement. |
12000 |
||||||||||||||
|
18 |
Fresh air flow meter |
PM11 |
Built in array thermal average wind speed sensor with parameter calibration function and interface. Color touch screen operation and display, data storage256Group, with time memory function. Airflow:85~3400m³/h;(50-2000cfm)wind speed0.2~7.6m/s;(0.56-25f/s)Temperature range:-10~80℃;(14-176°F)Accuracy of intake flow rate: ±(3%Reading ±12m³/h)Exhaust flow accuracy: ±(4%Reading ±12m³/h) |
20000 |
||||||||||||||
|
19 |
Intelligent landfill gas detector |
ETA-900 |
Detecting gases: methane, oxygen, carbon dioxide, hydrogen sulfide, temperature, humidity, etc. in the air6Parameter gases can be optionally selected. Simultaneously display the concentration of gas:ppmThemg/m3,temperature, humidity*Color touch screen display with time and date memory function*It has data query function and data storage256Group, there isUSBinterface*. |
30000 |
||||||||||||||
|
20 |
Ionization chamber monitoring instrument |
ET-451 |
Dose rate:0.1μSv/h—100mSv/h, Dosage:0.01μSv—999mSvAccuracy:≤±10%Energy response:6Kev—15Kev%±30%15Kev—100Kev±10% 100Kev—10mev±10% |
20000 |
||||||||||||||
|
21 |
Emergency detection box |
ET-I |
Including one electric sampling pump and a detection gas pipe50Only,QfitOne qualitative tightness tester3M-6200One half mask with dual filter box filtration. |
11000 |
||||||||||||||
|
22 |
Swimming pool water quality detector |
ET6010 |
Can detect residual chlorine, total chlorinePHValueORPDetection, high accuracy, simple operation |
6000 |
||||||||||||||
|
23 |
Food sampling box |
ET2012 |
Food poisoning samples, food(Braised food, pastries, tableware, etc)The sampling includes an alcohol lamp, high-pressure * * tank, sampling clamp, sterile culture dish, and aluminum alloy box |
2400 |
||||||||||||||
|
B:Atmospheric sampler (toxic gas sampler), dust sampler |
||||||||||||||||||
|
Preface |
Instrument name |
Type |
Technical Parameters |
price |
|
|||||||||||||
|
1 |
Toxic and harmful gas sampler |
ET-1 |
range:0.1~1.5L/min,Traffic, time, fully computerized automatic control and setting |
3000 |
|
|||||||||||||
|
|
Odor gas sampling box |
ETT - 1 |
Using high-quality gas sampling bags, with good airtightness, low adsorption, easy cleaning, and can be reused |
7800 |
|
|||||||||||||
|
2 |
Air sampling device |
ETKC-1 |
Can be performed simultaneously: atmospheric sampling, dust sampling |
5000 |
|
|||||||||||||
|
3 |
Air sampling device |
ETKC-2 |
Can be performed simultaneously: dual channel atmospheric sampling, six level microbial sampling |
12500 |
|
|||||||||||||
|
4 |
Microbial Air Monitoring Systems |
ETW-2 |
traffic5-35rise/Distributed and microcomputer controlled |
5600 |
|
|||||||||||||
|
5 |
Microbial Air Monitoring Systems |
ETW-6 |
traffic5-30rise/divide, Glass rotor flowmeter. Six level sampling |
9800 |
|
|||||||||||||
|
6 |
Intelligent Level 6 Air Microbial Sampler |
ETW-6A |
Sampling pump constant current sampling,Microcomputer controlled sampling, flow rate10-30 L/minadjustable |
12000 |
|
|||||||||||||
|
7 |
Aerosol Microbial Sampler |
ETW-3 |
Composed of impactor, acquisition board, front separator, main unit, and tripod |
15000 |
|
|||||||||||||
|
8 |
Intelligent aerosol microbial sampler |
ETW-3A |
Sampling pump constant current sampling, sampling flow rate10-30 L/minadjustable |
00 |
|
|||||||||||||
|
9 |
Microbial sampler for planktonic bacteria |
EKC-1 |
Sampling traffic:100L/minFixed flow sampling can be done from1~9999LAny setting. Timed sampling can be done from1~9999min,Can be set arbitrarily, using standard universal culture dishesΦ90*15 |
9800 |
|
|||||||||||||
|
10 |
Pocket atmospheric sampler |
TMP-1500 |
Range:0.1~1.5L/min, computer timing |
1600 |
|
|||||||||||||
|
11 |
Dual air path atmospheric sampler |
ETT-2000 |
Range:0.1~1.5L/minMicrocomputer timing |
2900 |
|
|||||||||||||
|
12 |
Intelligent dual channel atmospheric sampler |
ETT-2000A |
Sampling flow range:0.1-1.5Lmin(Can be expanded to2.0Lmin, dual flow) * * degree: ±2.5%. |
4000 |
|
|||||||||||||
|
13 |
Dust sampler |
ETF-30D |
Range:5-30L/min,Microcomputer timing |
3800 |
|
|||||||||||||
|
14 |
Individual dust sampler |
ETF-2 |
Range:0.1-3L/min,Electronic timing |
1500 |
|
|||||||||||||
|
15 |
Dual channel dust sampler |
ETF-30E |
Dual traffic:5~25L/minMicrocomputer timing |
4300 |
|
|||||||||||||
|
16 |
SKC Collection Efficiency |
ETF-30B |
Total dust, respiratory dust:5-30L/min |
5800 |
|
|||||||||||||
|
C:Various water quality samplers, sludge samplers |
||||||||||||||||||
|
Preface |
Instrument name |
type |
skill technique ginseng number |
price |
|
|||||||||||||
|
1 |
Standard sampling equipment |
ETC-3 |
Simultaneous sampling of soil, water quality, and air samples |
4200 |
|
|||||||||||||
|
2 |
Bottle type deepwater sampler |
ETC-1 |
Manual sampling, depth4Meter, sample size1L |
1200 |
|
|||||||||||||
|
|
Diamond Water Harvester |
ETC-00 |
It is resistant to falling, aging and corrosion, and its service life is ten times of that of the unified sampling barrel |
2000 |
|
|||||||||||||
|
3 |
Bucket type water quality sampler |
ETC-1A |
Manual sampling, depth15Meter, sample size4LTransparent with thermometer |
980 |
|
|||||||||||||
|
|
Bucket type deepwater sampler |
ETC-1A |
Manual sampling, depth15Meter, sample size1LTransparent with thermometer |
400 |
|
|||||||||||||
|
|
Bucket type deepwater sampler |
ETC-1A |
Manual sampling, depth15Meter, sample size2.5LTransparent with thermometer |
500 |
|
|||||||||||||
|
4 |
Stainless steel water quality sampler |
ETC-1B |
Manual sampling, depth15Meter, sample size4LManufacturing of stainless steel materials |
1200 |
|
|||||||||||||
|
|
Stainless steel water quality sampler |
ETC-1B |
Manual sampling, depth15Meter, sample size1LManufacturing of stainless steel materials |
900 |
|
|||||||||||||
|
|
Stainless steel water quality sampler |
ETC-1B |
Manual sampling, depth15Meter, sample size2.5LManufacturing of stainless steel materials |
1000 |
|
|||||||||||||
|
5 |
Handheld deepwater sampler |
ETC-2A |
Handheld, with rechargeable battery, depth:8rice |
8800 |
|
|||||||||||||
|
6 |
Automatic water quality sampler |
ETC-778 |
Automatic water sampling,Mixed up**,Timed setting |
4800 |
|
|||||||||||||
|
8 |
Fully automatic water quality sampler |
ETC-1000C |
Proportional automatic sampling, with cooling and constant temperature adjustment |
28000 |
|
|||||||||||||
|
9 |
Fully automatic water quality sampler |
ETC-1000 |
Automatic collection12Bottle only, timed, sampling volume:1000milliliter/bottle |
15500 |
|
|||||||||||||
|
|
Electric deep water sampler |
ET-QJDY |
Sampling depth can reach30Mi,50Mi,70Rice, users can choose and select by themselves |
9800 |
|
|||||||||||||
|
|
Manual deepwater sampler |
ET-D18 |
Large sampling depth: manually pump inflated underwater100M |
8000 |
|
|||||||||||||
|
|
Surface water sampler |
ET-8000D |
Fixed time quantitative sampling, fixed flow quantitative sampling, flow ratio sampling, liquid level ratio sampling, real-time quantitative sampling, etc |
15000 |
|
|||||||||||||
|
|
Soil solution sampler |
ET-SRQ |
Composed of water intake head, sampling bottle, and water intake pump |
6800 |
|
|||||||||||||
|
10 |
Manganese steel sludge sampler |
ETC-200 |
Grab bucket type, collecting sludge from the river |
3000 |
|
|||||||||||||
|
11 |
Stainless steel sludge sampler |
ETC-200 |
Stainless steel material grab bucket, collecting sludge from the river |
4600 |
|
|||||||||||||
|
|
Box type sludge sampler |
ETC-400A |
Stainless steel material grab bucket, collecting sludge from the river |
5800 |
|
|||||||||||||
|
|
Hanging rope sludge sampler |
ETC-3L |
Mud collection area:27cm×15cmMud collection depth:11cmVolume:3-4L |
4000 |
|
|||||||||||||
|
|
Hanging rope sludge sampler |
ETC-6L |
Mud collection area:38cm×21cmMud collection depth:15cmVolume:5-6L |
4600 |
|
|||||||||||||
|
12 |
Soil sampler (set) |
ETC-300A |
Four types of drill bits that can collect samples of different soil types |
8000 |
|
|||||||||||||
|
13 |
Soil sampler |
ETC-300 |
Heart shaped soil sampling drill, sampling depth1Rice: |
2000 |
|
|||||||||||||
|
14 |
Soil sampler kit |
ETC-300B |
Four types of drill bits, portable case, sample storage bottle, in storage bag |
16000 |
|
|||||||||||||
|
15 |
Soil moisture sampler |
ETC-300L |
Hard soil sampler: length700mm.Slime sampler: square push out type, length400mm |
780 |
|
|||||||||||||
|
16 |
Soil volumetric sampler |
ETC-300C |
Configuration: The entire set of samplers consists ofTComposed of a handle, drill rod, slide hammer, sampling ring liner holder, sampling ring (soil sample cup), sampling ring liner (drill barrel), and sample ejector |
15000 |
|
|||||||||||||
|
17 |
Sediment sediment sampler |
ETC-300E |
Collect underwater sediments (sediment, sediment, sludge), swamp soil, peat soil, etc. from rivers, lakes, etc. This sampler samples transparent organic glass sampling tubes, and the collected samples are clearly visible |
16000 |
|
|||||||||||||
|
18 |
Soil heavy metal analysis sampler |
ET0306 |
The stainless steel sampling tube is equipped with an internal engineering plastic cutting head, and the collected samples do not come into contact with metal |
16000 |
|
|||||||||||||
|
19 |
Gravity column sediment sampler |
ET0205 |
Unique water locking design. Stainless steel sleeve with built-in transparent sampling tube. Collect columnar undisturbed samples |
12000 |
|
|||||||||||||
|
20 |
Direct pressure semi-circular groove drill |
ET0302 |
Sampling diameter3cm, one sampling length20、50、100The120cm |
7500 |
|
|||||||||||||
|
21 |
Gasoline powered root drill |
ET0404 |
Sampling diameter20cmSampling depth:2Rice. Extension rod pin link |
12000 |
|
|||||||||||||
|
22 |
Soil organic matter sampler |
ET0305 |
Sampling tube diameter38mm, Long241mmSampling length20cm. Standard configuration sampling depth5m |
16000 |
|
|||||||||||||
|
23 |
Hard soil root drill |
ET0308 |
Sampling diameter5cmOne sampling length20cmSingle point sampling quantity1kg左右 |
15000 |
|
|||||||||||||
|
24 |
Foot splitting soil sampler |
ETC-130 |
Sampling depth:30cmSampling diameter:3cmSampling length:30cm |
0 |
|
|||||||||||||
|
25 |
Lawn sampler |
ETC-280 |
Lawn sampler, short handled soil sampler, soil profile sampler |
2500 |
|
|||||||||||||
|
26 |
Single drill |
ET0307 |
Sampling diameter10cmOne sampling length15cmTotal length114cm |
7500 |
|
|||||||||||||
|
27 |
Square soil undisturbed sampler |
ET0309 |
Sampling depth:2rice,Sampling edge length:15cm,Sampling length:25cm,Sample size:15kg |
9800 |
|
|||||||||||||
|
28 |
Manually rotate the sampling drill |
ET0301 |
Can collect different types of soil surface layers0-20cmThe sample can also be used for deep sampling |
9800 |
|
|||||||||||||
|
29 |
Soil cylindrical sampler |
ET0401 |
Sampling depth:2m,Sampling diameter:10cm,One time sampling length:100cm |
00 |
|
|||||||||||||
|
30 |
Soil crusher |
XA-C |
Capacity:50g、0-12000turn/divide |
1080 |
|
|||||||||||||
|
D:Analytical measuring instruments and equipment (acidity meter, mercury analyzer, conductivity meter, digestion instrument) |
||||||||||||||||||
|
Preface |
Instrument name |
Type |
Technical Parameters |
price |
|
|||||||||||||
|
1 |
Microcomputer mercury analyzer |
ETCG-2A |
Measurement range:0-10ng/mlLower limit0.05ng/ml Color touch screen operation, automatic storage of standard curves Concentration day reading, with258Group data storage, can be connected to a computer. |
16000 |
|
|||||||||||||
|
|
Dual beam cold atomic mercury analyzer |
ETCG-3 |
Measurement principle: dual beam,Measurement range:0-10ng/mlLower limit0.05ng/mlColor touch screen operation, automatic storage of standard curves |
26000 |
|
|||||||||||||
|
3 |
Multi parameter water quality detector(70) |
ET-70D |
Color touch screen operation and display, with storage function, direct reading of residual chlorine, turbidity, fluoride, nitrite, dissolved oxygen, etc. in water quality70parameter |
38000 |
|
|||||||||||||
|
4 |
Pesticide residue detector |
ET-8DN |
Color touch screen operation and display, with data storage and memory functions8-16Channel users can choose freely,3Minute direct detection displays measurement results |
15000 |
|
|||||||||||||
|
5 |
Acidity meter |
PHS-3C |
+0.01pHWarm compensation0-60℃、 two hundred and oneinterface |
2200 |
|
|||||||||||||
|
8 |
Digital conductivity meter |
DDS-11A |
0.0-199.9The1999us/cm |
1250 |
|
|||||||||||||
|
9 |
Digital conductivity meter |
DDS-12A |
0-2×105/0.5%,uS/cm |
2200 |
|
|||||||||||||
|
10 |
Digital spirometer |
SF-101 |
Measurement range:0-9990mlDigital display |
2800 |
|
|||||||||||||
|
|
Intelligent electronic spirometer |
SF-101A |
Measurement range:1-10000mlColor touch screen display with time and date memory function*Has data query function and data storage256Group, there isUSBinterface |
9800 |
|
|||||||||||||
|
11 |
Digital constant temperature digestion instrument |
DTD-25 |
Room temperature -300℃, digestive pore:18 |
4700 |
|
|||||||||||||
|
12 |
Aluminum digestion apparatus |
DTD-25 |
Aluminum blocks have faster and more stable thermal conductivity, and the number of holes is:18 |
6000 |
|
|||||||||||||
|
13 |
Microwave digestion instrument |
ET-WB |
Can measure the chemical oxygen demand in various types of surface water, domestic sewage, and industrial wastewater(CODcr)Total phosphorus(TP)Total nitrogen(TN)Perform rapid and efficient digestion determination |
9800 |
|
|||||||||||||
|
13 |
Food Physical and Chemical Quick Inspection Box |
ET90 |
The test results can be obtained in a few minutes, which is essential for sudden poisoning incidents. The type and detection limit of the test are nitrite:2.5mg/KgManganese:0.5mg/LCadmium:0.2mg/Kg,Lead:1 mg/L,Arsenic:0.1 mg/KgMercury:0.02mg/kgEnemy Mouse:0.025g/kg, Secure:0.02g/L, peroxide value:5 meq/KgAcid value:0.1 mgKoH/gCyanide:0.5mg/Kg,Organophosphorus pesticides:0.05mg/KgHistamine:0.7 mg/100g,Methanol:0.004g/100ml,Fusel oil:0.2g/L,Tung oil:0.3 g/100g,Aspergillus flavus**B1:2.5µg/Kg |
7900 |
|
|||||||||||||
|
14 |
Food * * Quick Inspection Box |
ET90 |
**Quick Sampling |
5900 |
|
|||||||||||||
|
15 |
Water quality physical and chemical rapid inspection box |
ET88 |
The test results can be obtained in a few minutes, which is essential for sudden poisoning incidents |
4900 |
|
|||||||||||||
|
16 |
Water Quality Quick Inspection Box |
ET88 |
**Quick Sampling |
4900 |
|
|||||||||||||
|
|
Water and poison detection box |
WEF91-2 |
The water and drug detection box can detect sensory, general physical and chemical, toxicological, chemical, military toxic agents, etc29Item indicators |
12800 |
|
|||||||||||||
|
17 |
Swimming pool water quality testing |
ET6010 |
Swimming pool water quality detector, detecting residual chlorine, total chlorinePHValue.ORPDetection, high accuracy, simple operation |
6000 |
|
|||||||||||||
|
18 |
Portable iron ion analyzer |
S-1T |
light source520nmDetermine the lower limit:0.10mg/LScope:0.00-3.00mg/LAccuracy ±5%Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
4500 |
|
|||||||||||||
|
19 |
Portable manganese ion analyzer |
S-1M |
light source520nmDetermine the lower limit:0.05mg/LScope:0.00-5.00mg/LAccuracy ±5%Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
4500 |
|
|||||||||||||
|
20 |
Portable turbidity meter |
S-1B |
light source520nmDetermine the lower limit:5NTUMeasurement range:0-400NTUMeasurement accuracy ±5%Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
5000 |
|
|||||||||||||
|
21 |
Portable residual chlorine analyzer |
S-1Y |
light source520nmStability: ±0.005Abs/20minDetermine the lower limit0.01mg/LScope:0.00-2.50mg/LTime <2minAccuracy ±5% Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
5000 |
|
|||||||||||||
|
22 |
Residual chlorine and total chlorine analyzer |
S-2Y |
light source520nmStability: ±0.005Abs/20minDetermination lower limit: residual chlorine0.01mg/LTotal Chlorine0.01mg/LScope: Residual chlorine0.00-2.50mg/Ltotal chlorine0.00-2.50mg/LTime <2minAccuracy ±5%Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
6000 |
|
|||||||||||||
|
23 |
Portable total hardness tester |
S-YD |
light source520nmDetermine the lower limit:1.0mg/LScope:0.0-500.0mg/LAccuracy ±5%Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
3800 |
|
|||||||||||||
|
24 |
Portable Three Nitrogen Detector |
S-3D |
light source520nmReading division:0.01 mg/LRange: Ammonia nitrogen 0.02~6mg/LNitrate nitrogen 0.50~10mg/LNitrite nitrogen 0.00~0.5mg/LMeasurement accuracy: Average deviation ≤3%±0.01Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
10500 |
|
|||||||||||||
|
25 |
Water quality ozone analyzer |
S-O3 |
light source520nmStability: ±0.005Abs/20minDetermine the lower limit0.05mg/LScope:0.00-2.50mg/LTime <3minAccuracy ±5% Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
6000 |
|
|||||||||||||
|
26 |
Water quality formaldehyde analyzer |
S-102 |
light source520nmDetermine the lower limit:0.05mg/LScope:0.00-1.50mg/LAccuracy ±5%Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
6000 |
|
|||||||||||||
|
27 |
Water quality chlorine dioxide analyzer |
S-CLO2 |
light source520nmStability: ±0.005Abs/20minDetermine the lower limit0.02mg/LScope:0.00-3.00mg/Ltime1minAccuracy ±5% Large color touch screen with time and date memory function*Has data query function and data storage256Group, there isUSBinterface*. |
5000 |
|
|||||||||||||
|
28 |
Multi parameter water quality analyzer6 |
ET-6D |
l Photoelectric colorimetric method, detection time5-30Minutes, large color touch screen, time and date memory function*Has data query function and data storage256The group hasUSBInterface.*Dissolved oxygen, ammonia nitrogen, nitrite,PH,Water temperature, salinity |
7200 |
|
|||||||||||||
|
29 |
Multi parameter water quality analyzer8 |
ET-8D |
As above, the parameters are as follows: residual chlorine, compound chlorine, total chlorine, ammonia nitrogen, dissolved oxygen, nitrite, iron, manganese |
8000 |
|
|||||||||||||
|
30 |
Multi parameter water quality analyzer11 |
ET-11D |
As above, the parameters are as follows: turbidity, residual chlorine, total chlorine, compound chlorine, chlorine dioxide, ammonia nitrogen, dissolved oxygen, nitrite, chromium, iron, manganese |
8800 |
|
|||||||||||||
|
31 |
Multi parameter water quality analyzer13 |
ET-13D |
As above, the parameters are as follows: turbidity, residual chlorine, total chlorine, compound chlorine, chlorine dioxide, ammonia nitrogen, dissolved oxygen, nitrite, chromium, iron, manganese, high ammonia nitrogen, chromaticity |
9500 |
|
|||||||||||||
|
32 |
Multi parameter water quality analyzer15 |
ET-15D |
As above, the parameters are as follows: residual chlorine, total chlorine, turbidity, fluoride, nitrite nitrogen, iron, manganese, dissolved oxygen, hexavalent chromium, sulfide, ammonia nitrogen, calcium, chemical oxygen consumption, ozone, total phosphorus can be selected for measurement |
11200 |
|
|||||||||||||
|
33 |
Multi parameter water quality analyzer20 |
ET-20D |
As above, the parameters are as follows: turbidity,High turbidity, residual chlorine,Compound chlorine,total chlorine,Chlorine dioxide,ammonia nitrogen,iron,suspended solids,dissolved oxygen,chromium,nitrite,chroma,High chromaticity, manganese,phosphate,nickel,,DPDresidual chlorine, DPDTotal chlorine, copper |
12800 |
|
|||||||||||||
|
34 |
Multi parameter water quality analyzer25 |
ET-25D |
Same as above, with the following parameters: Same as above, additionalTDS,temperature,COD(drop),Water hardness (drops),PH, five parameters |
14000 |
|
|||||||||||||
|
35 |
Multi parameter water quality analyzer35 |
ET-35D |
As above, the parameters are as follows: sulfate, cyanide, phosphate, volatile phenol, trivalent chromium, hexavalent chromium, sulfide, ammonia nitrogen, total hardness (drop), permanganate index(CODMn)(Drip), chemical oxygen consumption(CODCr)Ozone, total phosphorus, formaldehyde, zinc, aluminum, nickel, chromaticity, silver, copper, iron, manganese, calcium, cadmium, etc35item |
21000 |
|
|||||||||||||
|
36 |
Multi parameter water quality analyzer42 |
ET-42D |
As above, the parameters are as follows: chromaticity, high chromaticity, phosphate, anionic detergent, ozone, fluoride, chloride, sulfate, total phosphorus, nickel, iron, high-speed iron, chromium, manganese, copper, zincTDSTemperatureCOD(Manganese method)PHwait42item |
25000 |
|
|||||||||||||
|
37 |
Multi parameter water quality analyzer65 |
ET-65D |
As above, the parameters are as follows: sodium hypochlorite, nitrate, nitrate nitrogen, nitrite, nitrite nitrogen, ozone, cobalt, cyanide, molybdenum, phosphate, orthophosphate, silica, silver, sodium chromate, mercury, boron, lead, potassium, calcium, magnesium, chloride, etc65plant |
33000 |
|
|||||||||||||
|
E:City and county level equipment, anemometer, illuminance meter, temperature and humidity meter, sound level meter, energy leakage meter |
|
|||||||||||||||||
|
1 |
Digital noise meter |
TES-1350A |
30-130dB/digital display/big/Small noise |
1900 |
|
|||||||||||||
|
2 |
Portable ionization chamber inspection instrument |
ET-451 |
technical performance |
19800 |
|
|||||||||||||
|
3 |
Emergency detection box |
ET-I |
Qualitative and quantitative on-site real-time rapid detection of gases, including suitcases, gas masks, gas samplers, and manual samplers/Bag, oxygen/Combustible gas alarm, inorganic/Organic gas rapid detection tube(CO,CO2,H2S, SO2, NH3, Cl2,Gasoline, benzene, nitrogen oxides, liquefied petroleum gas |
10800 |
|
|||||||||||||
|
4 |
Food sampling box |
ET-2012 |
Specially suitable for sampling food poisoning samples, food (braised, pastry, tableware, etc.);Suitable for water quality sampling;Sampling for health and epidemic prevention laboratories;The same applies to sampling in other laboratories. |
3500 |
|
|||||||||||||
|
5 |
Microwave leakage energy meter |
ML-91 |
The working frequency band is:0.9-12.4GHZTwo sensors |
10800 |
|
|||||||||||||
|
6 |
Microwave leakage energy meter |
ML-91(Small) |
Testing Scope:0.01~106.94mW/cm2Working frequency:50MHz~3.5GHz |
9800 |
|
|||||||||||||
|
7 |
Digital atmospheric pressure gauge |
BY-2003P |
Digital display of atmospheric pressure, range:80-110KPResolution:0.1KP |
2450 |
|
|||||||||||||
|
8 |
Micro wind velocimeter |
BYWF-2001 |
High intensity probe/handheld/0.01~5m/s/Reading retention, rechargeable battery |
2900 |
|
|||||||||||||
|
9 |
Temperature, air volume, anemometer |
AVM- 01/03/05 |
wind speed0~45m/s, temperature0-60℃, 01For anemometer;03=Temperature+01;05=Air volume+03 |
1900/2100/ 2600 |
|
|||||||||||||
|
10 |
Digital illuminance meter |
TES-1330A |
0.01LUX ,0~20000LUX/digital display |
1000 |
|
|||||||||||||
|
11 |
Digital illuminance meter |
TES-1332 |
0.1LUX ,0~200000LUX/digital display |
1200 |
|
|||||||||||||
|
12 |
Digital temperature and humidity meter |
TES-1360 |
temperature-20℃~60℃,Humidity:10%RH~95%RH |
1900 |
|
|||||||||||||
|
13 |
Food Center Temperature Gauge |
WT-1 |
Temperature measurement range: -50℃- +300℃(-58℉∽+572℉) Resolution:0.1℃ Accuracy: ±1℃(-20℃∽+80℃) |
200 |
|
|||||||||||||
|
14 |
Laser rangefinder |
PD40 |
Accuracy: ±1.0MM measurement range(No target board):0.05M~100M Large measurement distance(There is a target board):200M |
2500 |
|
|||||||||||||
|
15 |
UV intensity meter (single channel) |
UV-B |
Range:0.1μW/μcm2~1.999×10^5 μW/cm^2,(0.1-199900Micro tile/square centimeter)divide4File switching Resolution:0.1Micro tile Accuracy:±5%(Compared to national standards) |
2500 |
|
|||||||||||||
|
16 |
ORPmeasuring instrument |
ORP-286 |
Measurement range:0±1999mVResolution:1 mV Accuracy:±5mvWorking voltage:0°C-60°C |
2500 |
|
|||||||||||||
|
17 |
Digital Breeze Meter |
T405 |
0~5m/s,0.01m/s |
0 |
|
|||||||||||||
|
18 |
Differential pressure gauge |
the testo 510 |
Accuracy: ±0.03 hPa (0 to 0.30 hPa) /±0.05 hPa (0.31 to 1.00 hPa) |
2500 |
|
|||||||||||||
|
19 |
turbidimeter |
XZ-1B |
0-20NTU, small indication value0.01 |
4800 |
|
|||||||||||||
|
20 |
Portable iron detector |
FE-1A |
Measurement range:0-0.8mg/LSmall indication:0.001mg/L |
2500 |
|
|||||||||||||
|
21 |
Portable manganese detector |
MN-1A |
Measurement range:0-0.5mg/LSmall indication:0.001mg/L |
2500 |
|
|||||||||||||
|
22 |
Portable Three Nitrogen Detector |
S-3N |
Range: Ammonia nitrogen 0.02~6mg/L; |
6800 |
|
|||||||||||||
|
23 |
Portable total hardness tester |
GDYS-102SB |
Determination of lower limit:1.0mg/L |
1900 |
|
|||||||||||||
|
24 |
Organophosphorus pesticide detector
|
PR-202SH-10 |
Sample testing quantity:10 a |
2500 |
|
|||||||||||||
|
25 |
Dust particle counter |
DT-9880 |
Chinese interface, simultaneously measuring data from six channels, ten thousandA data record 0.3to10Mmadjustable0.3/0.5/1/3/5/10Mm |
00 |
|
|||||||||||||
|
26 |
Pipeline robot |
S-101 |
Scope of application: The cross-section is68mm(high)×160mm(wide)Above, the slope is40° pipeline. |
85000 |
|
|||||||||||||
|
27 |
Surface thermometer |
DT-8830 |
-18℃~275℃ |
1380 |
|
|||||||||||||
|
28 |
Desk and chair ruler |
PR0360 |
4One direction360Complete measurement of degree,Multi purpose measuring tool, three in one protractor, inclinometer, and level ruler. |
1900 |
|
|||||||||||||
|
29 |
Radiation calorimeter |
MR-5 |
range0~10kW/m2 |
2200 |
|
|||||||||||||
|
30 |
Personal dose alarm device (wrist type) |
PM1208M |
Dose rate range:0.01~9999.99MSv/hDose range:0.001~9999.99 mSvRange of noise:0.06~1.5 MeV |
24000 |
|
|||||||||||||
|
31 |
Radiation suit |
ROHC |
Radiation protective clothing0.5mmPbOr above, long sleeved, double-sided, lead glass glasses0.5mmPbor above |
4400 |
|
|||||||||||||
|
32 |
Portable surface pollution meter |
BS9611 |
0~9999 CPSCounting:1~106-1Detection efficiency:E α≥30%?background≤3cpm,Eβ≥30%background≤150cpm |
16800 |
|
|||||||||||||
|
33 |
ATPdetector |
BioLum-ⅡTM |
Detection accuracy:4×10-18mol ATPDetection limit: The total amount of microorganisms detected can reach1.0 CFU/mlDetection range:0-9999 RLU(Relative luminous unit) |
15000 |
|
|||||||||||||
Price List for Other Products:
For water quality, a set of reagents is required(50It can be connected to a printer.
Price List for Other Products:
2018Jintan Yitong's quotation----County level health supervision department
2018Jintan Yitong's quotation----Municipal Health Supervision Department
2018Jintan Yitong's quotation----Laboratory instruments section
(1)The above product types and prices are for reference only.
(2)All ordering services are subject to consultation and contracts.
(3)Three guarantees for one year and lifetime maintenance for all products.
Changzhou Yitong 2018 quotation (analytical instrument part); Changzhou Yitong 2018 quotation (analytical instrument part);
Changzhou Yitong 2018 quotation (analytical instrument part); Changzhou Yitong 2018 quotation (analytical instrument part); Changzhou Yitong 2018 Quotation (Analytical Instrument Part)
Changzhou Yitong Analytical Instrument Manufacturing Co., Ltd
Huaxing Road, Jintan District, Changzhou City
electricity Words:
:-
:
: