Product Introduction of American Huarui SP-2104 Plus Toxic Gas Detector:
SP-2104 is a explosion-proof and fixed installation toxic gas detector. The detector adopts electrochemical sensor technology, with on-site LED display, infrared remote control adjustment and parameter setting functions, and can detect toxic and harmful gases such as CO and H2S.
Features of the American Huarui SP-2104 Plus Toxic Gas Detector:
Good selectivity
Has good selectivity, avoiding interference from other gases on the detected gas
Stable and reliable
In over a decade of industry applications, we have continuously provided users with continuous security guarantees
Multiple signal outputs
Standard 4-20mA (three wire system), two-level switch output, can be easily connected to industrial control systems such as PLC/DCS, and can also be used as a standalone control
Friendly human-machine interface
Intuitive and clear ultra-high brightness LED display and local alarm indication
No opening cover, infrared remote control operation
Integrated sound and light alarm (optional)
Prevent misoperation
The instrument has over range and inversion protection, which can avoid the danger caused by improper human operation. The remote control has detector recognition function and can achieve one-on-one operation
Stainless steel sensor components
Using stainless steel sensor components, it can be applied to complex and harsh working environments
Rich electrical interfaces
Featuring multiple electrical interfaces such as 3/4 "NPT F, 3/4" NPT M, 1/2 "NPT F/M, G3/4 F/M, etc., available for users to choose from
Petroleum, petrochemical, metallurgical, chemical, fire protection, gas, environmental protection, electricity, communication, papermaking, printing and dyeing, sewage treatment, food brewing, scientific research, education, national defense
Standard configuration
Detector host, operation manual, standard gas hood, installation accessories
Options
Sound and light alarm, remote control, standard gas, pressure reducing valve
Application areas of the American Huarui SP-2104 Plus toxic gas detector:
Petroleum and Petrochemicals
Metallurgy and Chemical Industry
Fire and gas
environment protection
Electricity and communication
Paper making, printing and dyeing
sewage treatment
Food Brewing
Research and Education
national defense
Technical parameters of the American Huarui SP-2104 Plus toxic gas detector:
Detection principle: electrochemistry
Sensor: Intelligent Sensor
Sampling method: diffusion type
Working power supply: 10~30VDC
High power: 60mA@24VDC
Output signal: 4~20mA, adjustable
Load impedance: 600 Ω
Other: Output alarm, fault relay 30VDC 2A (passive)
Detection accuracy: ± 2% F.S
Response time: (T90)<20s
Electrical interface: 3/4 "NPT M (optional 3/4" NPT F, 1/2 "NPT F/M, G3/4 F/M)
Installation method: 2 "riser/wall mounted installation
Display mode: LED display
Protection level: IP65
Environmental temperature: -40 ℃~+70 ℃ (very limited)
Environmental humidity: 10~93% RH (no condensation)
Environmental pressure: 86kPa~106kPa
Dimensions: 239mm × 189mm × 118mm (HWD)
Shell material: Aluminum alloy
Weight: 2.2kg
Explosion proof certification: Ex d II CT6